How To Detect Medical Cables?

Feb 28, 2023

Therefore, if we want to avoid these risks, we should strictly check and do a good job in quality inspection when accepting these medical cables. Do you know how to accept medical cables? Here is your introduction:


Steps for medical cable acceptance:

1. Data inspection:
Check the business license of the medical cable manufacturer, as well as the product production license, the product quality inspection report issued by the national accreditation agency (the official seal of the manufacturer must be affixed, and the official seal must be red), and the wire must have the CCC certification mark, CCC certification certificate, and the original product certificate of conformity; If there is no inspection report, product certificate and CCC certificate, these medical cable products must not be produced by regular manufacturers, and the quality cannot be guaranteed, so they should be rejected.


2. Outer package inspection:
Confirm that the medical cable package is complete, and the product brand, specification and model on the package should be consistent with the order requirements.


3. Physical inspection:
Ensure that the surface of medical cable conductor should be glossy and free of defects such as broken wire, loose strand, jumper, crush and burr; The surface of the insulation layer shall be smooth and flat with uniform color; The surface of the outer sheath shall be smooth and flat, with uniform color, without obvious knots, bulges, cracks, wrinkles, scratches and other phenomena; The surface of the armor layer shall be smooth and round without curling, burr, missing package and other defects; For medical cables with inkjet code on the surface, check whether the product name, specification and model are consistent with the order requirements.


4. Dimension and performance inspection:
The shortage of length is prohibited. Some manufacturers will cheat on the length in order to increase profits, so they must be carefully identified; The national standard stipulates that the length error shall not exceed 0.5% of the total length; The Engineering Department shall submit the medical cable for inspection in batches according to the local government regulations to test the electrical performance of the medical cable; In addition, some manufacturers will make the conductor thick on both sides and thin in the middle during the production process, which is also very difficult to detect. Therefore, we should pay special attention to the size and performance inspection of medical cables.


To sum up, it is the step of medical cable acceptance. Only qualified medical cables can be put into use. Otherwise, the medical cable that has not passed the acceptance of the medical cable is likely to cause irreversible losses, and even affect the property and life safety of everyone.